Idex-health-science MCP Process – version with Settings Menu Manuale Utente

Navigare online o scaricare Manuale Utente per Pompe Idex-health-science MCP Process – version with Settings Menu. IDEX Health & Science MCP Process – version with Settings Menu User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 64
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
1
MCP Process/ISMATEC SA/29.05.07/CB/GP
English FrançaisDeutsch
Betriebsanleitung
Operating Manual
Mode d‘emploi
Pumpen-
Antrieb
Mikroprozessor-
gesteuert
Schutzgrad IP 65
ISM 915
Für Pumpenköpfe:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Membran HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
WM 5
Pump
drive
Microprocessor
controlled
Protection rating IP 65
ISM 915
For pump heads:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Diaphragm HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
WM 5
MCP Process
Moteur de
pompe
Commandé par
microprocesseur
Classe de protection IP 65
ISM 915
Pour têtes de pompe:
Pro 280 / Pro 281
Pro 380 / Pro 381
360 / 380 / 380 AD
CA 4 / CA 8 / CA 12
FMI Q0 / Q1 / Q2 / Q3
Easy-Load
Standard
Quickload
MS 3
MS/CA 4-12 / MS/CA 8-6
PTFE Diaphragme HF/LF
PTFE Tube 2 mm / 4 mm
SB 2V / 3V / 5V
WM 5
29.05.07 CB/GP
Vedere la pagina 0
1 2 3 4 5 6 ... 63 64

Sommario

Pagina 1 - MCP Process

1MCP Process/ISMATEC SA/29.05.07/CB/GPEnglish FrançaisDeutschBetriebsanleitungOperating ManualMode d‘emploiPumpen-AntriebMikroprozessor-gesteuertSchut

Pagina 2

10MCP Process/ISMATEC SA/29.05.07/CB/GP Start-up informationAfter switching on the power sup-ply switch, the following values are displayed:1 LED

Pagina 3 -  Seite / page 47:

11MCP Process/ISMATEC SA/29.05.07/CB/GPOperating panel1 Digital LED display 2 Reduce value * settings3 Increase value4 RUN/STOP – Starts and stop

Pagina 4

12MCP Process/ISMATEC SA/29.05.07/CB/GP mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL Anzeige der BetriebsartLEDs for operating

Pagina 5

13MCP Process/ISMATEC SA/29.05.07/CB/GPbaMODEmmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL Control keysa RUN/STOP Starts and stops

Pagina 6

14MCP Process/ISMATEC SA/29.05.07/CB/GP settingsokdefaultabcdesettingsGrundeinstellungenBasic settingsRéglage de base*Control keys for basic setti

Pagina 7

15MCP Process/ISMATEC SA/29.05.07/CB/GPSelecting the basic settings1 Select the program (p. 20)2 Switch the pump off3 Keep the settings key pressed

Pagina 8

16MCP Process/ISMATEC SA/29.05.07/CB/GP Program specific basic settingsk Individually adjustable for each of the 4 programs.CyclesNumber of dispens

Pagina 9

17MCP Process/ISMATEC SA/29.05.07/CB/GPProgram specific basic settingsk Individually adjustable for each of the 4 programs.Foot switch– Toggle (default

Pagina 10 -  Avant de mettre la pompe

18MCP Process/ISMATEC SA/29.05.07/CB/GP okokokokokokMenu Grundeinstellungen verlassenQuit the menue basic settingsQuitte le menu des réglages de b

Pagina 11 - Flow rate

19MCP Process/ISMATEC SA/29.05.07/CB/GPPeristaltik-PumpenkopfPeristaltic pump head Tête péristaltiqueKolben-Pumpenkopf Piston pump headTête pistoniØ i

Pagina 12

2MCP Process/ISMATEC SA/29.05.07/CB/GP ContentsSafety precautions 4–5Warranty terms 6Product 7Rear panel 8Mains voltage 8Starting the pump 9

Pagina 13

20MCP Process/ISMATEC SA/29.05.07/CB/GP Program selectionWhen switching the pump on, it always selects the previously used program.1 Change mode

Pagina 14

21MCP Process/ISMATEC SA/29.05.07/CB/GPPumping by drive speed1 Change mode to PUMP rpm, 1.0 – 240.0 rpm, adjustable in steps of 0.1 rpm2 – Enter r

Pagina 15

22MCP Process/ISMATEC SA/29.05.07/CB/GP Pumping by flow rate1 Change mode to PUMP Flow rate 2 Enter the required flow rate with 56 keys (is disp

Pagina 16

23MCP Process/ISMATEC SA/29.05.07/CB/GPCalibrating the flow rate1 Change mode to PUMP Flow rate Enter the required flow rate with the 56 keys2 C

Pagina 17

24MCP Process/ISMATEC SA/29.05.07/CB/GP Dispensing by time The dispensing time can be en-tered from 0.10 s to 999 h.1 Change mode to DISP Time2

Pagina 18

25MCP Process/ISMATEC SA/29.05.07/CB/GPDispensing by volume1 Change mode to DISP Volume2 Use the 56 keys for entering the required dispensing volum

Pagina 19

26MCP Process/ISMATEC SA/29.05.07/CB/GP Calibrating the volume1 Change MODE to DISP Volume k Use the 56keys for entering the required

Pagina 20 -  Dès à présent, toutes les

27MCP Process/ISMATEC SA/29.05.07/CB/GPMODE1mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL CALmmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVol

Pagina 21

28MCP Process/ISMATEC SA/29.05.07/CB/GP mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolume

Pagina 22

29MCP Process/ISMATEC SA/29.05.07/CB/GPIntermittent dispensing (by time)Intermittent dispensing by time with a pre-set pause time1 Go to mode PAUSE T

Pagina 23

3MCP Process/ISMATEC SA/29.05.07/CB/GPContentsDispensing by volume within a pre-set time 28Intermittent dispensing by time 29 by volume 30No.

Pagina 24

30MCP Process/ISMATEC SA/29.05.07/CB/GP mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolume

Pagina 25

31MCP Process/ISMATEC SA/29.05.07/CB/GPmmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGRAMFlow rateTOTAL mmrpmTimeTimeTUBE I.D. PUMPDISPPAUSEVolumePROGR

Pagina 26

32MCP Process/ISMATEC SA/29.05.07/CB/GP Drip-free dispensingReverse roller steps (backsteps) allow drip-free dispensing (1 to 100 roller steps). W

Pagina 27

33MCP Process/ISMATEC SA/29.05.07/CB/GPPumping against pressureThe MCP Process can be used for continuous duty at a differential pressure of max. 1.5

Pagina 28

34MCP Process/ISMATEC SA/29.05.07/CB/GP Overcurrent protectorThe drive MCP Process features an overload protector. When an over-load condition occ

Pagina 29 - (Zeiteinheit)

35MCP Process/ISMATEC SA/29.05.07/CB/GPHinweisWir verweisen auf unsere ausführli-che Schlauch-Dokumentation.Please notePlease refer to our detailed tu

Pagina 30 - (Volumen)

36MCP Process/ISMATEC SA/29.05.07/CB/GP Analog interfacePin 1, GND (ground)Reference potential for all other inputsPin 2, remoteFor changing betwe

Pagina 31

37MCP Process/ISMATEC SA/29.05.07/CB/GPAnalog interfacePin 9, speed OUTThe default setting is 0 – 10 VDC, proportionally to the motor speed 0 – 240.0

Pagina 32 -  Erste Dosierung verwerfen

38MCP Process/ISMATEC SA/29.05.07/CB/GP Réglages du switch S1Commutateur coulissant S2Cet interrupteur influence le pin 9, speed OUTPosition A: 0

Pagina 33 -  Rückflussgefahr

39MCP Process/ISMATEC SA/29.05.07/CB/GPSerial interfaceRS232 IN (female)A 9-pin D-socket is available on the rear panel of the pump.Setting the pump a

Pagina 34

4MCP Process/ISMATEC SA/29.05.07/CB/GP Safety precautionsISMATEC® Pumps are designed for pumping applications in laborato-ries and industry. As su

Pagina 35

40MCP Process/ISMATEC SA/29.05.07/CB/GP Serial interfaceRS232 OUT (male)Pin 2: RS232 RxIs used for connecting additional pumps together with pin

Pagina 36

41MCP Process/ISMATEC SA/29.05.07/CB/GPSerielle Schnittstelle / Serial interface / Interface sérielle Befehl Funktion / Beschreibung Beispiel

Pagina 37

42MCP Process/ISMATEC SA/29.05.07/CB/GP Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel A

Pagina 38 -  Remarque

43MCP Process/ISMATEC SA/29.05.07/CB/GPSerielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel Antwor

Pagina 39 - GND RxD TxD

44MCP Process/ISMATEC SA/29.05.07/CB/GP Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel A

Pagina 40

45MCP Process/ISMATEC SA/29.05.07/CB/GPSerielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel Antwor

Pagina 41

46MCP Process/ISMATEC SA/29.05.07/CB/GP Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel A

Pagina 42

47MCP Process/ISMATEC SA/29.05.07/CB/GPJede Pumpe braucht eine eigene Adresse. (siehe Seite 39).Each pump requiresan individual address. (see page 39)

Pagina 43 - 100 mm) 1+0320

48MCP Process/ISMATEC SA/29.05.07/CB/GP Logiciel de programmationLogiciel ProgEdit Créez votre programme d'application individuel. Chargez

Pagina 44

49MCP Process/ISMATEC SA/29.05.07/CB/GPAccessoiresCarte d’interface Moxa C168incluant un câble multiple avec fiches 25 pôles (mâle) pour com-mander un

Pagina 45 - 10 sec.)

5MCP Process/ISMATEC SA/29.05.07/CB/GPSafety precautions Do not manipulate the pump head before the pump is swit-ched off and disconnected from the

Pagina 46

50MCP Process/ISMATEC SA/29.05.07/CB/GP Cassettes de rechangeCassettes de rechange en POM-C CA Click'n'go cassette IS 3710CA levier de

Pagina 47

51MCP Process/ISMATEC SA/29.05.07/CB/GP2-Stopper-Schläuche2-stop collared tubingTubes à 2 arrêtsAccessoiresMatériau POM-CCopolymère de polyoxyméthylèn

Pagina 48 - 2", Win95

52MCP Process/ISMATEC SA/29.05.07/CB/GP MontageJedem Pumpenkopf liegt eine Mon-tageanleitung bei.Vor Inbetriebnahme den korrekten ID-Code eingeben

Pagina 49

53MCP Process/ISMATEC SA/29.05.07/CB/GPedoCDI*.oNDI.rN-lletseB.oNredrOednammocedoNnetarßeilFsetarwolFtibéDnim )nim/lm( xamkcurDnoisserPerusserP)rab(sl

Pagina 50

54MCP Process/ISMATEC SA/29.05.07/CB/GP epyT/pyT epyT/pyTepyT/pyTepyT/pyT epyT/pyT3SM 3SM3SM3SM 3SM6-8AC/SM 6-8AC/SM6-8AC/SM6-8AC/SM 6-8AC/SM21-4A

Pagina 51

55MCP Process/ISMATEC SA/29.05.07/CB/GPepyT/pyTV2BSV3BS063083DA083082-orP182-orPxuanaC/slennahC2 3 1 1 1 1 1nellornepmuPstellaG/srelloR6 6 3 3 3 2 2py

Pagina 52

56MCP Process/ISMATEC SA/29.05.07/CB/GP  HinweisBei den Angaben in den nachfol-genden Tabellen handelt es sich nur um Richtwerte, die wie folgt

Pagina 53 - .oNredrO

57MCP Process/ISMATEC SA/29.05.07/CB/GPOuverture du boîtier Afin de garantir l’étanchéité du boîtier, il est recommandé de n’ouvrir la pompe que pour

Pagina 54 -  Remarque

58MCP Process/ISMATEC SA/29.05.07/CB/GP Opening the casing hoodSealing the casing hoodWhen the casing hood fits tight, each single screw must be r

Pagina 55 - Pumpenkanäle

59MCP Process/ISMATEC SA/29.05.07/CB/GPRemplacement des fusiblesLes fusibles sont fixés sur le tab-leau de commande (dessus) et sur le tableau réseau (

Pagina 56

6MCP Process/ISMATEC SA/29.05.07/CB/GP Warranty termsWe warrant the perfect functio-ning of our products, provided they have been installed and op

Pagina 57 -  Um die Dichtigkeit des Ge

60MCP Process/ISMATEC SA/29.05.07/CB/GP MaintenanceProvided the MCP Process is ope-rated properly and in compliance with this manual, the tubing i

Pagina 58 -  Die Wahl eines Schnitt

61MCP Process/ISMATEC SA/29.05.07/CB/GP HinweisBeachten Sie ebenfalls unsere Ga-rantie- und allgemeinen Verkaufs- und Lieferbedingungen.Bitte setzen

Pagina 59

62MCP Process/ISMATEC SA/29.05.07/CB/GP

Pagina 60

63MCP Process/ISMATEC SA/29.05.07/CB/GPRESETMINMINMAXRESETMINMINMAXMINMINMINCALMINCALMINCALMINCALMINCALMINCAL2x, or/oderOFFFlow rateVolumeFlow rateVol

Pagina 61

64MCP Process/ISMATEC SA/29.05.07/CB/GP ISMATEC® Vertretung/Representative/ReprésentationISMATEC® - Ihr kompetenter Partner für anspruchsvolle Pu

Pagina 62

7MCP Process/ISMATEC SA/29.05.07/CB/GPProduct Contents of the package MCP Process drive Magnet included Order No. ISM 915 incl. integrated power

Pagina 63 - PROGRAM

8MCP Process/ISMATEC SA/29.05.07/CB/GP Panneau arrière1 Interrupteur principal2 Prise d’alimentation 3 RS232 IN (entrée femelle)4 RS232 OUT (s

Pagina 64

9MCP Process/ISMATEC SA/29.05.07/CB/GPStarting the pump Mount the pump head accor-ding to the mounting instruc-tion manual supplied with the pump he

Commenti su questo manuale